Padronização Primária do Radionuclídeo 123I

Autores

  • Regio dos Santos Gomes LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI/IRD/CNEN), https://orcid.org/0000-0003-1282-2629 (não autenticado)
  • Carlos José Da Silva LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI/IRD/CNEN)
  • José Ubiratan Delgado LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI/IRD/CNEN)
  • Monica Aguiar Leobino da Silva LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes
  • R.L. da Silva LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI/IRD/CNEN)
  • Johnny de Almeida Rangel LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes
  • Luis Alberto Pereira Dias IPEN/CNEN , Instituto de Pesquisas Energéticas e Nucleares image/svg+xml
  • Alfredo Lopes Ferreira Filho LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes
  • Octavio L. Trindade Filho LMNRI/IRD/CNEN , Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI/IRD/CNEN)

DOI:

https://doi.org/10.15392/2319-0612.2025.2969

Palavras-chave:

Medicina Nuclear, Radiofármaco, Padronização Primária, Iodo

Resumo

Radionuclídeos de meia-vida curta são essenciais para a Medicina Nuclear. Esses radionuclídeos geralmente se ligam a uma estrutura molecular ou celular mais complexa e com características farmacológicas; esse conjunto é chamado de "radiofármaco" e tem sido aplicado no diagnóstico e terapia de doenças. O uso de radiofármacos envolve exposição à radiação ionizante, que, embora cuidadosamente controlada, apresenta riscos potenciais à saúde de pacientes e profissionais de saúde. Desse modo, para minimizar esses riscos e manter os benefícios do uso de radiofármacos, a dose administrada deve ser determinada com alta exatidão e precisão. Essa necessidade impõe aos Institutos Nacionais de Metrologia (INMs) o requisito de aprimorar as técnicas de padronização primária desses radionuclídeos, de modo que a calibração dos medidores de atividade em hospitais e clínicas de medicina nuclear tenha a maior acurácia e precisão possível. O iodo-123 é utilizado para diversas aplicações em radiodiagnóstico, sendo as principais o diagnóstico de patologias e tumores da tireoide. Neste trabalho apresenta-se a padronização primária do 123I realizada por contagem em anticoincidência 4παβ(LS)γ(NaI(Tl)) em tempo vivo, na qual impurezas radionuclídicas significativas não foram detectadas por espectrometria de raios gama de alta resolução. Com esse trabalho o LMNRI/IRD preparou-se para a comparação-chave da série K4 do BIPM utilizando o instrumento SIRTI.

Downloads

Os dados de download ainda não estão disponíveis.

Biografia do Autor

  • Regio dos Santos Gomes, LMNRI/IRD/CNEN, Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI/IRD/CNEN),

    Born in the city of Duque de Caxias in the state of Rio de Janeiro, he is a federal public servant at CNEN - National Nuclear Energy Commission (CNEN), assigned to IRD - Institute of Radioprotection and Dosimetry, working as Head of Service of the Division of Metrology of Ionizing Radiation designated by INMETRO, as National Laboratory of Metrology of Ionizing Radiation (LNMRI / IRD / CNEN). Coordinates scientific projects with BIPM and LNHB, both from France, Coordinates the PNI - National Program for Intercomparison of Activity Measurements in Environmental Samples. Secretary of Scientific Publication of the Brazilian Society for Radiological Protection (SBPR), being responsible for the journal BJRS - Brazilian Journal of Radiation Science, which we managed, in 2024, to include in the SCIELO collection. Doctoral and Master's student in Radioprotection and Dosimetry of the postgraduate course at IRD / CNEN in the area of ​​​​Metrology of Ionizing Radiation. Bachelor of Physics from the Federal University of Rio de Janeiro (UFRJ) with experience in the Nuclear area. Systems and support analyst trained, through mentoring, by the Training Manager of IBM/Brazil. He has been a physics and mathematics teacher since 1991 in universities, schools and preparatory courses for public exams, has 15 years of experience in the nuclear area working with open radioactive sources for use in research, medical and industrial applications, photon spectrometry using high-purity germanium detectors (HPGe), Absolute Radionuclide Standardization systems TDCR (Triple-to-Double Coincidence Ratio) developed at LNMRI/IRD/CNEN and the commercial HIDEX SL 300. Has training in Nuclear and Radiation Emergency Response by the Emergency Division of IRD/CNEN. He has over 30 years of experience in Information Technology in developing Commercial, Industrial, Automation and Web systems in several programming languages ​​such as LabVIEW, Python, C++, PHP, JavaSript, HTML, CSS, Visual Basic, Fortran, Pascal, Clipper and Delphi. Databases: Oracle, MySQL, PostgreSQL, Firebird, Access and Dbase. Experience and work with ABNT ISO/IEC 17025, 17043 standards. He is support Vasco da Gama.

Referências

[1] Zimmerman, B.E. Radionuclide metrology in the life sciences: Recent advances and future trends. Applied Radiation and Isotopes, v. 64, p. 1351–1359, 2006. DOI: https://doi.org/10.1016/j.apradiso.2006.02.044

[2] Michotte, C.; Nonis, M..; Bobin, C.; Altzizoglou, T.; Sibbens, G. The SIRTI: a new tool developed at the BIPM for comparing activity measurements of short-lived radionuclides world-wide. Bureau International des Poids et Mesures, Rapport BIPM-2013/02, Pavillon de Breteuil, F-92312 SÈVRES Cedex, France, 2013.

[3] Chang, M.-C.; Peng, C.-L.; Chen, C.-T.; Shih, Y.-H.; Chen, J.-H.; Tai, Y.-J.; Chiang, Y.-C. Iodine-123 Metaiodobenzylguanidine (I-123 MIBG) in Clinical Applications: A Comprehensive Review. Pharmaceuticals, v. 17, p. 1563-1588, 2024. DOI: https://doi.org/10.3390/ph17121563

[4] Catanoso, M. F. Purificação de 123I e 131I para marcação de biomoléculas. 2011. Dissertação (Mestrado em Tecnologia Nuclear - Aplicações) - Instituto de Pesquisas Energéticas e Nucleares, Universidade de São Paulo, São Paulo, 2011.

[5] LNHB/CEA, Laboratoire National Henri Becquerel, 2004. Table of Radionuclides. 〈www.nucleide.org/DDEP_WG/123_tables〉 accessed at 06-11-2025.

[6] Zimmerman, B. E.; Collé, R. & Fitzgerald, R. Developments in the standardization and activity measurements of iodine-123. Applied Radiation and Isotopes, v. 87, p. 322-325, 2014.

[7] Sahagia, M.; Antohe, A.; Ivan, C. & Luca, A. Standardization of ¹²³I by the 4πβ(PC)-γ coincidence method and comparison with other methods. Applied Radiation and Isotopes, v. 68, p. 1417-1420, 2010.

[8] Gomes, R. S. Determinação das probabilidades de emissão gama do 229Th e seus descendentes. Master's dissertation (Master in Radioproteção e Dosimetria - Metrologia), Instituto de Radioproteção e Dosimetria, Comissão Nacional de Energia Nuclear, Rio de Janeiro, 2021.

[9] Schrader, H. Ionization chamber. Metrologia, v.44, p S53-S66, 2007. DOI: https://doi.org/10.1088/0026-1394/44/4/S07

[10] Da Silva, C.J. Implementação de um sistema de Anticoincidência 4 NaI(Tl)-CL com cronometragem em tempo vivo e tempo morto estendível. Tese (Doutorado em Ciências em Engenharia Nuclear), COPPE, Programa de Engenharia Nuclear, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 2008.

[11] SIR Transfer Instrument - Protocol for the continuous activity comparisons at the NMIs BIPM.RI(II)-K4 Version 3.4, Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312 SÈVRES Cedex, France, 2023.

[12] Schrader, H.; Klein, R.; Kossert. K. Activity standardization of 18F and ionization chamber calibration for nuclear medicine. Applied Radiation and Isotopes, v. 65, p. 581–592, 2007. DOI: https://doi.org/10.1016/j.apradiso.2007.01.002

[13] ISO/IEC 17025:2017 - General requirements for the competence of testing and calibration laboratories. 3rd ed. International Organization for Standardization, 2017.

[14] ICRU Report 95 - Operational Quantities for External Radiation Exposure. Journal of the ICRU, 20(1). Bethesda, International Commission on Radiation Units and Measurements. SAGE Publications, 2020.

[15] ICRP Publication 128. Radiation Dose to Patients from Radiopharmaceuticals: A Compendium of Current Information Related to Frequently Used Substances. SAGE Publications, 2015.

Downloads

Publicado

29-08-2025

Edição

Seção

Artigos