Um novo método de voxelização de fantomas mesh através de imagens transversais

Autores

  • Raniele Costa de Matos dos Santos UFPE , Universidade de Pernambuco image/svg+xml
  • Whoody Alem Wanderley Araripe Farias UFPE , Universidade de Pernambuco image/svg+xml
  • José Wilson VIEIRA IFPE e UPE , Universidade de Pernambuco image/svg+xml , Instituto Federal de Educação, Ciência e Tecnologia de Pernambuco image/svg+xml
  • Pedro Henrique Avelino de ANDRADE IFPE , Instituto Federal de Educação, Ciência e Tecnologia de Pernambuco image/svg+xml
  • Jefferson Melo Gonçalves PENA IFPE , Instituto Federal de Educação, Ciência e Tecnologia de Pernambuco image/svg+xml
  • Vanildo Júnior de Melo LIMA UFPE , Universidade Federal de Pernambuco image/svg+xml
  • Fernando Roberto de Andrad LIMA CRCN , Centro Regional de Ciências Nucleares do Nordeste

DOI:

https://doi.org/10.15392/2319-0612.2025.2912

Palavras-chave:

Fantomas, Voxelização, Monte Carlo, Radiação ionizante

Resumo

Modelos Computacionais de Exposição (MCEs) utilizam algoritmos de fontes de radiação ionizante e códigos Monte Carlo (MC) para simular o transporte da radiação, sua interação com a matéria e avaliar a energia depositada em volumes de interesse (VOIs) representados por um fantoma. O GDN (Grupo de Pesquisa em Dosimetria Numérica) (CRCN-NE) e Grupo de Pesquisa em Dosimetria Computacional e Sistemas Embarcados (IFPE)) têm desenvolvido técnicas e softwares para criar fantomas antropomórficos Boundary Representation (BREP), os quais normalmente são construídos por malhas poligonais devido a melhor representação anatômica de órgãos e tecidos. Para acoplar os fantomas BREP aos códigos MC, o GDN desenvolveu um método que converte malhas poligonais em voxels. Esse processo é realizado por meio do software in-house DIP (Digital Image Processing), que converte arquivos mesh.obj em voxels.sgi (simulações gráficas interativas). Neste estudo é apresentada uma nova técnica de voxelização a partir de imagens coronais geradas de um fantoma mesh utilizando o aplicativo Blender e os softwares in-house DIP e PHAntoms Manufacturing. Essencialmente, o método consiste em usar um plano para seccionar o volume que contém o fantoma no sentido anteroposterior, salvando a imagem de cada corte. O total de imagens geradas é ajustado para reproduzir a altura do fantoma de 176 cm, visando voxels cúbicos com arestas de 0,12 cm, o que correspondeu a 272 imagens. As imagens produzidas representam uma coleção de VOIs segmentados com identificadores unívocos empilhadas no DIP, criando um arquivo SGI. O resultado dessa voxelização foi comparado com o método anterior do GDN para análises dosimétricas das radiações ionizantes.

Downloads

Os dados de download ainda não estão disponíveis.

Referências

[1] COSTA, Y. A. P., DO VAL IETSUGU, M., BOLOGNESI, L. Efeitos biológicos da radiação e síndrome aguda das radiações. Tekhne e Logos, Florianópolis, v. 15, n. 1, p. 121-136, 2024.

[2] YORIYAZ, Hélio. Método de Monte Carlo: princípios e aplicações em Física Médica. Revista Brasileira de Física Médica, São Paulo, v. 3, n. 1, p. 141-149, 2009.

[3] VIEIRA, J. W., CABRAL, M. O. M., ANDRADE, P. H. A., NETO, V. L., LIMA, V. J. M., LIMA, F. R. A. (2018). Uso do software DIP para voxelização de fantomas mesh. PROTEÇÃO CONTRA RADIAÇÕES NA COMUNIDADE DOS PAÍSES DE LÍNGUA PORTUGUESA, p. 27.

[4] ANDRADE, P. A., VIEIRA, J. W., OLIVEIRA, V. R. S., VELOSO, R. J. B., LIMA, F. R. A. Um método para voxelização de geometrias 3D de malhas. Brazilian Journal of Radiation Sciences, São Paulo, v. 8, n. 1A (Suppl.), p. 1-12, 2020. DOI: https://doi.org/10.15392/bjrs.v8i1A.1000

[5] CASSOLA, V. F., LIMA, V. J. M., KRAMER, R., KHOURY, H. J. FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy. Physics in Medicine & Biology, v. 55, n. 1, p. 133, 2009. DOI: https://doi.org/10.1088/0031-9155/55/1/009

[6] CASSOLA, V. F. KRAMER, R., BRAYNER C., KHOURY, H. J. Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection. Physics in Medicine & Biology, v. 55, n. 15, p. 4399, 2010. DOI: https://doi.org/10.1088/0031-9155/55/15/014

[7] CASSOLA, V. F. et al. Standing adult human phantoms based on 10th, 50th and 90th mass and height percentiles of male and female Caucasian populations. Physics in Medicine & Biology, v. 56, n. 13, p. 3749, 2011. DOI: https://doi.org/10.1088/0031-9155/56/13/002

[8] CASSOLA, V. F., MILIAN, F. M., KRAMER, R., LIRA, C. A. B. O., KHOURY, H. J. Development of newborn and 1-year-old reference phantoms based on polygon mesh surfaces. Journal of Radiological Protection, v. 33, n. 3, p. 669, 2013. DOI: https://doi.org/10.1088/0952-4746/33/3/669

[9] LIMA, V. J. M., CASSOLA, V. F., KRAMER, R., LIRA, C. A. B. O., KHOURY, H. J., VIEIRA, J. W. Development of 5‐and 10‐year‐old pediatric phantoms based on polygon mesh surfaces. Medical physics, v. 38, n. 8, p. 4723-4736, 2011. DOI: https://doi.org/10.1118/1.3615623

[10] BLENDER FOUNDATION. Blender 2.91.0 Manual de referência. Disponível em: <https://download.blender.org/release/Blender2.91/>. Acesso em: 05 nov. 2024.

[11] CASSOLA, Vagner Ferreira. Desenvolvimento de fantomas humanos computacionais usando malhas poligonais em função da postura, massa e altura. 2011. Tese (Doutorado) – Programa de Pós-Graduação em Tecnologias Energéticas e Nucleares, Universidade Federal de Pernambuco, Recife, 2011.

[12] IMAGEJ. Version 1.54: National Institutes of Health. Disponível em: <https://imagej.softonic.com.br/>. Acesso em: mar. 2025.

[13] ANDRADE, Pedro Henrique Avelino de. Construção e voxelização de um fantoma mesh masculino adulto com macro circulação e vasos linfáticos. 2018. Tese (Doutorado) – Programa de Pós-Graduação em Tecnologias Energéticas e Nucleares, Universidade Federal de Pernambuco, Recife, 2018.

[14] FARIAS, Whoody Alem Wanderley Araripe. Desenvolvimento de uma plataforma computacional para a geração de fantomas antropomórficos e fontes emissoras de elétrons. 2023. Dissertação (Mestrado em Tecnologias Energéticas e Nucleares) – Departamento de Energia Nuclear, Universidade Federal de Pernambuco, Recife, 2023.

[15] ICRP. Basic Anatomical and Physiological Data for Use in Radiological Protection Reference Values. ICRP Publication 89. Ann. ICRP, v. 32, n. 3-4, 2002. DOI: https://doi.org/10.1016/S0146-6453(03)00002-2

[16] ICRU - International Commission on Radiation Units and Measurements. Tissue substitutes in radiation dosimetry and measurement. ICRU Report 44. U.S.A., ICRU, 1989.

[17] ICRU - International Commission on Radiation Units & Measurements. Photon, electron, proton and neutron interaction data of body tissues. ICRU Report No. 46. Bethesda: ICRU, 1991.

[18] KAWRAKOW, I.; MAINEGRA-HING, E.; ROGERS, D. W. O.; TESSIER, F.; WALTERS, B. R. B. The EGSnrc Code System: Monte Carlo simulation of electron and photon transport. Technical Report PIRS-701. Ottawa, Canada: National Research Council Canada, 2017.

Downloads

Publicado

25-08-2025