A PROPOSAL OF PROCESS VALIDATION IN THE IMPLEMENTATION OF GOOD MANUFACTURING PRACTICES IN BRACHYTHERAPY SOURCES PRODUCTION

Autores

DOI:

https://doi.org/10.15392/bjrs.v9i1A.1285

Palavras-chave:

GMP, process validation, brachytherapy, iodine-125 seeds

Resumo

New laboratories for brachytherapy sources production are being implemented in our facility at IPEN, in São Paulo. A great challenge implementing a production laboratory is to comply with the Good Manufacturing Practices (GMPs), which involves process validation and all supporting activities such as cleaning and sanitization. Much more than compliance with regulatory guidelines, required for certification and inspections, a validation builds large process knowledge, provides possibilities for optimization and improvement, increasing the degree of maturity of all people involved and the quality system. The process validation results in a document that certifies that any procedure, process, equipment, material, operation or system leads to the expected results. This work focused on the new laboratory, been assembled to produce small iodine-125 seeds. The process validation was performed three times for evaluation. The parameters evaluated in this study were: the source welding efficiency and the leakage tests results (immersion test). The welding efficiency doesn’t have an established parameter, since is visually evaluated by the operator, and the leakage detection must be under 5 nCi / 185 Bq, accordingly with the ISO 9978. We observed values were average 79-87% production efficiency and leakage tests were under 5 nCi/seed. Although established values for the global efficiency aren’t available in the literature, the results showed high consistency and acceptable percentages, especially when other similar manufacturing processes are used in comparison (average 85-70% found in the literature for other similar metallic structures). Those values will be important data when drafting the validation document and to follow the Good Manufacturing Practices (GMPs).process

Downloads

Os dados de download ainda não estão disponíveis.

Biografia do Autor

  • Tatyana Spinosa Baptista, Nuclear and Energy Research Institute, (IPEN / CNEN - SP)
    Radioation Technology Center
  • Anselmo Feher Feher, Nuclear and Energy Research Institute, (IPEN / CNEN - SP)
    Radioation Technology Center
  • Bruna Teiga Rodriguez, Nuclear and Energy Research Institute, (IPEN / CNEN - SP)
    Radioation Technology Center
  • Carlos Alberto Zeituni, Nuclear and Energy Research Institute, (IPEN / CNEN - SP)
    Radioation Technology Center
  • João Augusto Moura, Nuclear and Energy Research Institute, (IPEN / CNEN - SP)
    Radioation Technology Center
  • Maria Elisa Rostelato, Nuclear and Energy Research Institute, (IPEN / CNEN - SP)
    Radioation Technology Center

Referências

LEITE, E.T; SILVA, J.L; CAPELLETTI, E; HADDAD, C.M; MARTA, G.N. Prostate brachytheraphy with iodine-125 seeds: analysis of a sing institutional cohort. Int Braz.J. Urol, Vol. 25 (2), pp.288-2989 (2019).

WORLD HEALTH ORGANIZATION. Cancer, http://www.who.int/cancer/en/ (2019).

EU Guidelines to Good Manufacturing Practice Medicinal Products for Human and Veterinary Use. Annex 1: Manufacture of Sterile Medicinal Products (2008).

BRASIL. Anvisa. Resolução RDC nº 16. Good Manufacturing Practice Medicinal Products for Human (2013).

INTERNATIONAL STANDARD ORGANIZATION. Radiation protection – sealed radioactive sources – leakage test methods. (ISO - 9978) (1992).

Downloads

Publicado

30-04-2021

Edição

Seção

The Meeting on Nuclear Applications (ENAN) 2019

Como Citar

A PROPOSAL OF PROCESS VALIDATION IN THE IMPLEMENTATION OF GOOD MANUFACTURING PRACTICES IN BRACHYTHERAPY SOURCES PRODUCTION. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 9, n. 1A, 2021. DOI: 10.15392/bjrs.v9i1A.1285. Disponível em: https://www.bjrs.org.br/revista/index.php/REVISTA/article/view/1285. Acesso em: 20 jul. 2025.