Automation of Sample Handling for ORTEC’s Lead-Shielded High-Purity Germanium Gamma-Ray Detector
Automatización del manejo de muestras para el detector de rayos gamma de germanio de alta pureza blindado con plomo de ORTEC
DOI:
https://doi.org/10.15392/2319-0612.2026.3019Palavras-chave:
Autosampler, HPGe detector, Linear actuators, Arduino, ProgrammingResumo
Gamma spectroscopy is a non-destructive technique for identifying and quantifying radionuclides in environmental samples. High-purity germanium (HPGe) detectors are commonly used for these analyses. To minimize background radiation from sources other than the sample, the detector is housed in a lead shield. ORTEC’s low-background shield, weighing approximately 1180 kg, poses challenges for automation, making such systems rare and commercially expensive. Additionally, HPGe detectors require cooling to cryogenic temperatures, typically achieved using liquid nitrogen (LN2). The drawbacks of LN2 include its high cost and the limited duration of a 30 L LN2 charge (around 14 days), regardless of detector operation. An autosampler, an automated sample-handling system, optimizes LN2 usage by enabling sample changes during idle periods. In this work, we developed a cost-effective and efficient autosampler incorporating a “pick and place” robot and a pneumatic circuit for sample manipulation, linear actuators for automated door operation, and an electronic system integrated with “Maestro” (ORTEC’s spectroscopy software) via a custom-developed Python interface. This system integrates mechanical design, electronics, and programming to enhance efficiency, optimize LN2 usage and reduce downtime, thereby improving overall operational performance.
Downloads
Referências
[1] WALLBRINK, P. J.; WALLING, D. E.; HE, Q. Radionuclide measurement using HPGe gamma spectrometry. In: ZAPATA, F. (Ed.). Handbook for the assessment of soil erosion and sedimentation using environmental radionuclides. Springer, Dordrecht, 2002. p. 67-96. ISBN 978-0-306-48054-6. DOI: https://doi.org/10.1007/0-306-48054-9_5
[2] GONÇALVES, M. F.; FERREIRA, A. C. M.; OLIVEIRA, A. B.; ALMEIDA, J. C. T.; CUNHA, M. P. S. A. Monitoring of radionuclides in water for human consumption in the county of Angra dos Reis. Brazilian Journal of Radiation Sciences, v. 9, n. 2, p. 01-23, 2021. DOI: https://doi.org/10.15392/bjrs.v9i2.1685
[3] LIM, S. I.; HUH, J. Y.; LEE, E. K.; et al. Development of a HPGe shielding system for radioactivity measurements at Cheongpyeong Underground Radiation Laboratory. Journal of the Korean Physical Society, v. 69, n. 11, p. 1666-1672, 2016. DOI: https://doi.org/10.3938/jkps.69.1666
[4] BAGINOVA, M.; VOJTYLA, P.; POVINEC, P. P. The neutron component of background of an HPGe detector operating in a surface laboratory. Applied Radiation and Isotopes, v. 166, p. 109422, 2020. DOI: https://doi.org/10.1016/j.apradiso.2020.109422
[5] POLACZEK-GRELIK, K., KISIEL, J., WALENCIK-ŁATA, A. et al. Lead shielding efficiency from the gamma background measurements in the salt cavern of the Polkowice–Sieroszowice copper mine. Journal of Radioanalytical and Nuclear Chemistry, v. 308, p. 773–780, 2016. DOI: https://doi.org/10.1007/s10967-015-4567-6
[6] CARVALHO, M. C.; SANDERS, C. J.; HOLLOWAY, J. Auto-HPGe, an autosampler for gamma-ray spectroscopy using high-purity germanium (HPGe) detectors and heavy shields. HardwareX, v. 4, p. e00040, 2018. DOI: https://doi.org/10.1016/j.ohx.2018.e00040
[7] NUVIATECH INSTRUMENTS. ASC - Automatic Sample Changer. Available at: https://www.nuviatech-instruments.com/product/nulab-asc/. Accessed on: 11 nov. 2025.
[8] ANTECH INC. Automated Gamma Spectroscopy System (AGSS). Available at: https://www.antech-inc.com/product/automated-gamma-spectroscopy-system-agss/. Accessed on: 11 nov. 2025.
[9] UPP, D.; KEYSER, R.; TWOMEY, T. New cooling methods for HPGE detectors and associated electronics. Journal of Radioanalytical and Nuclear Chemistry, v. 264, n. 1, p. 121-126, 2005. DOI: https://doi.org/10.1007/s10967-005-0684-y
[10] MELO, G. R. DE; ZAHN, G. S.; GENEZINI, F. A.; MOREIRA, E. G. Development of an environmental monitoring station for HPGe detectors. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-14, 2021. DOI: https://doi.org/10.15392/bjrs.v9i1A.1412
[11] SPONG, M. W.; HUTCHINSON, S.; VIDYASAGAR, M. Robot modeling and control. Wiley, 2020. ISBN 978-1-119-52404-5.
Downloads
Publicado
Declaração de Disponibilidade de Dados
All data and software supporting this study are available from the corresponding author on reasonable request.
Edição
Seção
Licença
Direitos autorais (c) 2026 Carolina Campagna-Sánchez, Jenny Gómez-Avila, Grey Dorian Guzmán-Tejada, Jose Ramón Alvarez, Gabriela Beatriz Grad, Edgardo Venusto Bonzi, Jorge Torres-Díaz

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/