Source-detector effective solid angle calculation using MCNP6 code
DOI:
https://doi.org/10.15392/bjrs.v9i1A.1471Palavras-chave:
effective solid angle, NaI(Tl) detector, MCNP6 codeResumo
Nuclear techniques based on the attenuation of gamma radiation are used in the industry to calculate flow rate, determine fluid density, predict inorganic scale in oil pipelines, evaluate industrial mixers, among other applications. In order to use these nuclear techniques is necessary to perform studies of important parameters of radioactive source and radiation detectors, which are part of the measurement geometry, such as detection efficiency and solid angle. The aim of this study is to calculate the solid angle and the effective solid angle subtended by a NaI(Tl) detector. The effective solid angle considers attenuation in the medium (between source and detector) and other effects of radiation interaction with matter. Mathematical models were developed using the MCNP6 code in order to evaluate the proposed measurement geometry. The source was placed in different positions to the detector to evaluate frontal and lateral solid angle contributions, which is an important parameter to obtain the intrinsic efficiency response function. The simulated model consists of a NaI(Tl) scintillator detector and two point isotropic sources (241Am and 137Cs). The results for the geometry used in this study showed that the difference between solid angle and effective solid angle reached 20.17% for 241Am and 2.58% for 137Cs, which means that it is highly recommended to consider the effective solid angle in the calculations.Downloads
Referências
WIELOPOLSKI, L. The Monte Carlo calculation of the average solid angle subtended by a right circular cylinder from distributed sources. Nuclear Instruments and Methods, Vol. 143, pp. 577 – 581, 1977.
DORON, O. Simulation of an INS Soil Analysis System, pp. 154, The University of Texas at Austin, USA, 2007.
WHITCHER, R. A Monte Carlo method to calculate the average solid angle subtended by a detector to an ellipsoidal surface or solid source at any position and orientation. Radiation Protection Dosimetry, Vol. 149, No. 4, pp. 444 – 453, 2012.
NICOLAOU, G. The solid angle subtended by a well-type detector and a cylindrical source. Applied Radiation and Isotopes, 74, pp. 9 – 12, 2013.
MASKET, A. V. H.; MACKLIN, R. L.; SCHMITT, H. W. Tables of Solid Angles and Activations U.S. Atomic Energy Commission Report ORNL‐2170. Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA, 1956.
TSOULFANIDIS N. Measurement and Detection of Radiation. Series in Nuclear Engineering McGraw-Hill, 1983.
VERGHESE, K.; GARDNER, R.P.; FELDER, R.M. Solid angle subtended by a circular cylinder. Nucl. lnstr. and Meth., 101, 391 – 393, 1972.
PRATA, M.J. Analytical calculation of the solid angle defined by a cylindrical detector and a point cosine source with orthogonal axes. Radiation Physics and Chemistry, 66, 387–395. 2003.
THABET, A.A.; HAMZAWY, A.; BADAWI, M. S. New mathematical approach to calculate the geometrical efficiency using different radioactive sources with gamma-ray cylindrical shape detectors, Nuclear Engineering and Technology, 52, 1271 – 1276, 2020.
CARCHON, R.; VAN CAMP, E.; KNUYT, G.; VAN DE VYVER, R.; DEVOS, J.; FERDINANDE, H. A general solid angle calculation by a Monte Carlo method, Nucl. Instr. and Meth., 128, 195 – 199, 1975.
DAM, R. S. F.; SANTOS, A. G. M.; BARBOSA, C. M.; SALGADO, W. L.; SALGADO, C. M.; SILVA, A. X. Solid angle study of a NaI(Tl) detector using 198Au gamma ray source and MCNP6 code, In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, 2019, Santos, Associação Brasileira de Energia Nuclear, 2019. 1417 – 1424.
PELOWITZ, D.B. MCNP6 TM User’s Manual, Version 1.0, LA-CP-13-00634, Rev. 0. Los Alamos National Laboratory, USA, 2013.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/