Assessment of energy and angular dependence of LiF:Mg,Ti dosimeters irradiated in the quantity Hp(0.07)

Authors

DOI:

https://doi.org/10.15392/2319-0612.2023.2142

Keywords:

Dosimetry, extremidade, Hp(0.07)

Abstract

Radiation dosimetry has the purpose of quantifying the dose received by the occupationally exposed individual. The device used in this process is called a dosimeter, the dosimeter can be used in different situations, for example, the dosimeter used to quantify the dose received in the fingers is the ring model dosimeter, for the extremity, which is the focus of this work. In Brazil, we still do not have standards for the calibration of extremity dosimeters, therefore, in this work, the CASEC recommendations were used, adapted for extremity dosimetry. For a dosimeter to be used in its respective routine, it must present results within some pre-established limits in reference standards. For this purpose, energy dependence and angular dependence tests were carried out. To calibrate the LiF:Mg,Ti thermoluminescent dosimeters, a phantom rod was used. The phantom rod has the function of simulating the region of interest, in the case of this work, the fingers. The dosimeters were irradiated in the magnitude Hp(0.07), with the doses and energies recommended by the CASEC standard. The aim of this work is to characterize end dosimeters in the ring model with LiF:Mg,Ti detectors.

Downloads

Download data is not yet available.

References

NASCIMENTO, G. et al. Characterization and calibration of thermoluminescent dosimters of LiF: Mg, Ti in the quantity Hp (0.07), INAC, 2021.

ICRP, International Commission on Radiological Protection. The recommendations of the Internation Commission on Radiological Protecion. Publication 103, 2007.

SQUAIR, P. L., NOGUEIRA, M. S., OLIVEIRA, P. M. C. Calibração e Caracterização de Dosímetros de Extremidade. Santos, INAC, 2005.

CASEC, Comitê de Avaliação de Serviços de Ensaio e Calibração, Desempenho de Monito-ração Individual – Critérios e Condições, 2013.

OKUNO, Emico; YOSHIMURA, Elisabeth Mateus. Física das radiações. Oficina de Textos, 2016.

Harshaw-Bicron, model 4500 TLD Workstation Operators Manual, Publication N°4500-0- 0-0598-002, 1998.

ICRU, International Commission on Radiation Units and Measurements, Measurement of Dose Equivalent from External Photon and Electron Radiation, Report 47, 1992.

Downloads

Published

2023-06-13

How to Cite

Assessment of energy and angular dependence of LiF:Mg,Ti dosimeters irradiated in the quantity Hp(0.07). Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 11, n. 1A (Suppl.), p. 01–11, 2023. DOI: 10.15392/2319-0612.2023.2142. Disponível em: https://www.bjrs.org.br/revista/index.php/REVISTA/article/view/2142.. Acesso em: 8 may. 2024.

Similar Articles

1-10 of 441

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)