Dose sensitivity of MAGIC-f polymer gel using different MRI sequences

Authors

DOI:

https://doi.org/10.15392/2319-0612.2022.2085

Keywords:

dosimetric gel, MAGIC-f, 3D Dosimetry, magnetic resonance, spin echo

Abstract

This study aims to evaluate the dose sensitivity of MAGIC-f  gel irradiated by high-energy photon beams, comparing quantification using different MRI sequences. Irradiation was performed using 6 MV photons with 600 cGy/min dose rate, field size of 20x20 cm², and 94 cm source-to-surface distance. Two gel batches were produced on different days and placed in vials. In the first batch, doses of 0, 2, 4, 6, 8, 10, 20, and 40 Gy were planned. The second batch was irradiated with doses of 0, 2, 4, 6, 10, 12, 14, and 16 Gy. MR images were acquired with Spin Echo (SE, TR=3 s) and Multi Spin Echo (MSE, TR = 3s or 10s, turbo factor 24) sequences. The dose is assessed via changes in the transverse relaxation time in the irradiated gel. In MSE, dose sensitivity in the first batch was 0.27 (TR=3 s) and 0.28 Gy-1s-1  (TR=10 s) and in the second batch, 0.31 and 0.31 Gy-1s-1 (TR = 3 s and TR = 10 s, respectively). In the SE sequence, dose sensitivity was 0.42 for the first batch and 0.43 Gy-1s-1 for the second batch. Linearity of dose-response was only obtained for doses below 10 Gy. Comparing the dose sensitivity extracted from MSE and SE sequences using TR= 3s, differences around 30% were found. Thus, although MSE-MRI offers a faster protocol of imaging acquisition it is less precise for quantification of relaxation times, as TE is not a well-defined quantity. The performance of the gel as a dosimeter is consequently sequence dependent.

Downloads

Download data is not yet available.

References

Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M, et al. Polymer gel dosimetry. Phys Med Biol. 2010;55(5). DOI: https://doi.org/10.1088/0031-9155/55/5/R01

Silveira MA, Pavoni JF, Baffa O. Three-dimensional quality assurance of IMRT prostate plans using gel dosimetry. Phys Medica [Internet]. 2017;34:1–6. Available from: http://dx.doi.org/10.1016/j.ejmp.2016.12.007 DOI: https://doi.org/10.1016/j.ejmp.2016.12.007

Pavoni JF, Pastorello BF, De Arajo DB, Baff. Formaldehyde increases MAGIC gel dosimeter melting point and sensitivity. Phys Med Biol. 2008;53(4). DOI: https://doi.org/10.1088/0031-9155/53/4/N04

Mather ML, Whittaker AK, Baldock C. Ultrasound evaluation of polymer gel dosimeters. Phys Med Biol. 2002;47(9):1449–58. DOI: https://doi.org/10.1088/0031-9155/47/9/302

Jirasek A, Hilts M. An overview of polymer gel dosimetry using x-ray CT. J Phys Conf Ser. 2009;164. DOI: https://doi.org/10.1088/1742-6596/164/1/012038

De Deene Y. How to scan polymer gels with MRI? J Phys Conf Ser. 2010;250:69–78. DOI: https://doi.org/10.1088/1742-6596/250/1/012015

SCHWARCKE MMB. Caracterização do Gel Polimérico MAGIC-f para Aplicação em Medicina Nuclear Utilizando Imagens de Ressonância Magnética. 2013.

Pavoni JF, Baffa O. An evaluation of dosimetric characteristics of MAGIC gel modified by adding formaldehyde (MAGIC-f). Radiat Meas. 2012;47(11–12):1074–82. DOI: https://doi.org/10.1016/j.radmeas.2012.10.004

Khan M, Heilemann G, Kuess P, Georg D, Berg A. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels. Phys Med Biol. 2018;63(6). DOI: https://doi.org/10.1088/1361-6560/aab00b

Khan M, Heilemann G, Berg AG, Lechner W, Georg D. Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on. Polymers (Basel). 2019;11:E1717. DOI: https://doi.org/10.3390/polym11101717

Lizar JC, Volpato KC, Brandão FC, da Silva Guimarães F, Arruda GV, Pavoni JF. Tridimensional dose evaluation of the respiratory motion influence on breast radiotherapy treatments using conformal radiotherapy, forward IMRT, and inverse IMRT planning techniques. Phys Medica. 2021;81(November 2020):60–8. DOI: https://doi.org/10.1016/j.ejmp.2020.11.036

Maraghechi B, Gach HM, Setianegara J, Yang D, Li HH. Dose uncertainty and resolution of polymer gel dosimetry using an MRI guided radiation therapy system’s onboard 0.35 T scanner. Phys Medica [Internet]. 2020;73(March):8–12. Available from: https://doi.org/10.1016/j.ejmp.2020.04.004. DOI: https://doi.org/10.1016/j.ejmp.2020.04.004

Acurio ESR, Lizar JC, Arruda GV, Pavoni JF. Technical Note: Three-dimensional QA of simultaneous integrated boost radiotherapy treatments by a dose-volume histogram methodology and its comparison with 3D gamma results. Med Phys. 2021. DOI: https://doi.org/10.1002/mp.14859

Pavoni JF, Neves-Junior WFP, Da Silveira MA, Haddad CMK, Baffa O. Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique. Med Phys. 2017;44(9):4869–79. DOI: https://doi.org/10.1002/mp.12400

Resende TD. Um estudo para otimização da formulação do dosímetro gel MAGIC- f e avaliação da sua reutilização Sumário. Universidade de São Paulo; 2017.

Downloads

Published

2022-12-20

Issue

Section

Articles

How to Cite

Dose sensitivity of MAGIC-f polymer gel using different MRI sequences. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 10, n. 4, p. 1–15, 2022. DOI: 10.15392/2319-0612.2022.2085. Disponível em: https://www.bjrs.org.br/revista/index.php/REVISTA/article/view/2085.. Acesso em: 29 apr. 2024.

Similar Articles

1-10 of 292

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)