Appreciation of influence of acquisition parameters in analysis of root canal using microCT system

Authors

  • Luan Ferreira Bastos Federal University of Rio de Janeiro https://orcid.org/0000-0001-9948-5500
  • Olga Maria Oliveira de Araújo
  • Caio Márcio Sorrentino de Freitas Farias dos Santos
  • Tâmara Porfíro Teixeira
  • Renata Périssé Nobili Funcke
  • João Carlos Rocha de Lima
  • Alessandra Silveira Machado
  • Davi Ferreira Oliveira
  • Ricardo Tadeu Lopes

DOI:

https://doi.org/10.15392/bjrs.v9i1A.1552

Keywords:

microtomography, parameter comparison, root canal study

Abstract

Microtomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the acquisition process, as two matrix sizes: 1120x1120 pixels and 2240x2240 pixels. After the reconstruction, the volume of the root canal was analyzed, as well as the quantification of a remaining tooth closure material. The results showed that the detector array 1120X1120 was able to capture values close to those of the 2240x2240 matrix for the volume of root canal and for the residual material after treatment. Remaining tooth closure material correspond an average of 0.95 mm³ for 1120x1120 pixels, while the corresponding volume for 2240x2240 pixels was 0.90 mm³. Results for root canal volume average was 10.32 mm³ for 1120x1120 pixels, while for 2240x2240 pixels was 10.22 mm³. In this way, the difference of the detected volume between the two matrices is of 5.47% for the residual material and 0.93% for root canal volume. In a qualitative analyze, the 2240x2240 matrix allows the identification of a greater amount of details. However, it was possible to verify that depending on the application and the region of interest studied the smaller matrix can offer reliable results and a shorter processing time.

Downloads

Download data is not yet available.

Author Biography

  • Luan Ferreira Bastos, Federal University of Rio de Janeiro
    Nuclear Instrumentation Laboratory/Coppe

References

Robinson, J. P; Lumley, P. J; Cooper, P. R; Grover, L. M; Walmsley, A. Damien. Reciprocating Root Canal Technique Induces Greater Debris Accumulation Than a Continuous Rotary Technique as Assessed by 3-Dimensional Micro–Computed Tomography. Journal of Endodontics, v. 39(8), pp. 1067-1070, 2013.

Almeida, B. C; Ormiga, F; de Araújo, M. C. P; Lopes, R. T; Lima, I. C. B; dos Santos, B. C; Gusman, H. Influence of Heat Treatment of Nickel-Titanium Rotary Endodontic Instruments on Apical Preparation: A Micro-Computed Tomographic Study. Journal of Endodontics, v. 41(12), pp. 2031-2035, 2015.

Neves, A. A; Silva, E. J; Roterm, J. M; Belladona, F. G; Alves, H. D; Lopes, R. T; Paciornik, S; De‐Deus, G. A. Exploiting the potential of free software to evaluate root canal biomechanical preparation outcomes through micro-CT images. International Endodontic Journal, v. 48(11), pp. 1033-1042, 2015.

De-Deus, G; Belladonna, F. G; Silva, E. J. N. L; Marins, J. R; Souza, E. M; Perez, R; Lopes, R. T; Versiani, M. A; Paciornik, S; Neves, A. A. Micro-CT Evaluation of Non-instrumented Canal Areas with Different Enlargements Performed by NiTi Systems. Brazilian Dental Journal, v. 26(6), pp. 624-629, 2015.

Kierklo, A; Tabor, Z; Pawinska, M; Jaworska, M. A Microcomputed Tomography-Based Comparison of Root Canal Filling Quality following Different Instrumentation and Obturation Techniques. Medical Principles and Pratice, v. 24(1), pp. 84-91, 2015.

Alves, F. R. F; Marceliano-Alves, M. F; Sousa, J. C. N; Silveira, S. B; Provenzano, J. C; Siqueira, J, F. Removal of Root Canal Fillings in Curved Canal Using Either Reciprocating Single- or Rotary Multi-instrument Systems and a Supplementary Step with the XP-Endo Finisher. Journal of Endodontics, v. 42(7), pp. 1114-1119, 2016.

De-Deus, G; Carvalhal, J. C. A; Belladonna, F. G; Silva, E. J. N. L; Lopes, Lopes, R. T; Moreira Filho, R. E; Souza, E. M; Provenzano, J. C; Versiani, M. A. Dentinal Microcrack Development after Canal Preparation: A Longitudinal in Situ Micro-computed Tomography Study Using a Cadaver Model. Journal of Endodontics, v. 43(9), pp. 1553-1558, 2017.

Zuolo, M. L; De-Deus, G; Belladonna, F. G; Silva, E. J. N. L; Lopes, R. T; Souza, E. M; Versiani, M. A; Zaia, A. A. Micro-computed Tomography Assessment of Dentinal Micro-cracks after Root Canal Preparation with TRUShape and Self-adjusting File Systems. Journal of Endodontics, v. 43(4), pp. 619-622, 2017.

Al-Dameh, A; Braga, T; Love, R. M; de Camargo, J. M. P; Alcalde, M. P. Microcomputed tomography evaluation of maxillary molars mesiobuccal canal preparation using BioRaCe and AlphaKite rotary NiTi systems. Dental Press Endodontics, v. 8(2), pp. 29-35, 2018.

Moraes,R. R; Santos, T. M. P; Marceliano-Alves, M. F; Pintor, A. V. B; Lopes, R. T; Primo, L. G; Neves, A. A. Reciprocating instrumentation in a maxillary primary central incisor: A protocol tested in a 3D printed prototype. International Journal of Pediatric Dentistry, v. 29(1), pp. 50-57, 2019.

Marceliano Alves, M. F; Lima, C. O; Bastos, L. G. P. M. N; Bruno, A. M. V; Vidaurre, F; Coutinho, T. M; Fidel, S. R; Lopes, R. T. Mandibular mesial root canal morphology using micro-computed tomography in a Brazilian population. Australian Endodontic Journal, v. 45(1), pp. 51-56, 2019.

Angerame, D; De Biasi, M; Brun, F; Turco, G; Franco, V. Computed microtmography study of untreated, shaped and filled mesiobuccal canals of maxillary first molars. Australian Endodontic Journal, v. 45(1), pp. 72-78, 2019.

Stringheta, C. P; Bueno, C. E. S; Kato, A. S; Freire, L. G; Iglecias, E. F; Santos, M; Pelegrine, R. A. Micro-computed tomographic evaluation of the shaping ability of four instrumentation systems in curved root canals. International Endodontic Journal, v. 52(6), pp. 908-916, 2019.

Downloads

Published

2021-04-30

Issue

Section

The Meeting on Nuclear Applications (ENAN) 2019

How to Cite

Appreciation of influence of acquisition parameters in analysis of root canal using microCT system. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 9, n. 1A, 2021. DOI: 10.15392/bjrs.v9i1A.1552. Disponível em: https://www.bjrs.org.br/revista/index.php/REVISTA/article/view/1552.. Acesso em: 3 may. 2024.

Similar Articles

1-10 of 442

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

1 2 > >>