Different parameters should be monitored at a nuclear facility. Among them, water used in a nuclear reactor must meet strict specifications. The research reactor Argonauta, located in Rio de Janeiro, uses light water as both moderator and coolant. Quality control is the set of measurements to ensure, at any time, products that meet the parameters and standards in force. Then, the quality control of Argonauta’s water encompasses physical-chemical and radiological tests that are performed periodically to monitor deviations in the water parameters specification. These tests include the measurement of pH, conductivity, and gamma spectroscopy. By means of these tests, it is possible to evaluate if the quality parameters of this water meet the requirements defined by the reactor manufacturer and the Radiation Protection standards.  In this way, the safe operation of the Argonauta is guaranteed, besides avoiding unwanted exposures of operators and the environment to the ionizing radiation. This work presents the detailed assays performed in the water quality control. In addition, the obtained results in the last year measurements and highlights of the improvements to be done are also addressed. Moreover, a comparison among other research reactors in Brazil concerning this monitoring is presented. The obtained results indicate that pH, conductivity, and radiological parameters meet the established limits.

Downloads

Download data is not yet available.

References

IAEA – International Atomic Energy Agency. Guidebook on quality control of water reactor fuel. IAEA Technical report series 221, Vienna & Austria, 1983. 230p.

RENKE, C. A. C.; FERREIRA, F. J. O. Operation of the Argonauta Reactor. Prog Rep, v. 3, p. 70, 2013.

IEN – Instituto de Engenharia Nuclear. Sistema de purificação e tratamento de água do reator Argonauta. Comunicação técnica DIFIR 02/89, Rio de Janeiro, 1989. 23p.

IEN – Instituto de Engenharia Nuclear. Manual de operação do reator Argonauta. Relatório Técnico IEN/CNEN, Rio de Janeiro, 1990. 105p.

CEGALLA M. A., NETO A. J. S.; LONGO, E. S. Controle de qualidade da água da piscina do reator IEA-R1, avaiable at:<https://www.ipen.br/biblioteca/cd/inac/1999/PDF/CG31AA.PDF> Last accessed: 10 Feb. 2019.

PEREIRA, C. S.; ARAÚJO, V. P. Determination of Sodium in Argonauta reactor water. Prog Rep, v. 2, p. 97, 2009.

IEN – Instituto de Engenharia Nuclear. Metodologia para Medição e Determinação da Radioatividade na Água do Reator Argonauta. Relatório Técnico IEN/CNEN, Rio de Janeiro, 2006. 25p.

JURAN, J. M., DE FEO, J. A. Juran's Quality Handbook: The Complete Guide to Performance Excellence, 6th ed. New York: McGraw-Hill Education, 2010.

IAEA – International Atomic Energy Agency. Quality assurance for safety in Nuclear Power Plants and other Nuclear Installations - Code and Safety Guides Q1-Q14. Safety Series 50-C/SG-Q, Vienna & Austria, 1996. 235p.

CARVALHEIRA L.; RAMOS L. L.; NUNES R. C.; DOMINGUES A. M.; OLIVEIRA F. J. F. Water quality control for the Argonauta reactor in Rio de Janeiro, In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, 2019, Belo Horizonte. Annals… Belo Horizonte. Comissão Nacional de Energia Nuclear, 2019. p. 312-320.

CDTN – Centro de Desenvolvimento da Tecnologia Nuclear. Avaliação dos resultados analíticos – Programa de controle físico-químico da água de refrigeração do reator TRIGA IPR-R1. Publicação CDTN 983, Minas Gerais, 2014. 17p.